1.Designed refrigeration condition:Chillered water in/out is 12℃/7℃;Cooling water in/out is 30℃ and 35℃; 2.Suitable chilled water temperature:9-25℃; 3.Power supply:380V-3PH-50HZ.With allowable difference:±10%,allowable voltage difference between phase:±2%; 4.The specification is based on R22,contact us if need for R134a,R407C and other refrigerant;1
Description: It is a kind of regulating valve with simple structure. The butterfly valve that can be used for on-off control of low-pressure pipeline medium refers to a kind of valve whose closing part (disc or butterfly plate) is a disc, which rotates around the valve shaft to achieve opening and closing. Valves can be used to control the flow of 1
Description: Self-operated control valve, also known as self-operated control valve, is a control valve that relies on the pressure and temperature of the medium flowing through the valve as an energy source to drive the valve to work automatically, without external power supply and secondary instruments. Self-operated control valves are mainly div1
Water pump are widely used in below systems Water treatment systems Industrial washing systems Water supply systems Firefighting systems Cooling/air-conditioning systems Boiler feed systems Other industrial applications
Description: Centrifugal pumps work by using the rotation of the impeller to make water produce centrifugal movement. Before the pump is started, the pump casing and suction pipe must be filled with water, and then the motor is started, so that the pump shaft drives the impeller and water to make high-speed rotation. The water produces centrifugal 1
Descriptiopn The cryogenic storage tank has a double-layer vacuum insulation structure, the inner tank material is austenitic stainless steel, the outer container material is Q235-B or 345R, the inner and outer containers are filled with insulation materials and vacuumed. Pressure vessel Features a. High vacuum degree b. Inner and outer1
Description: 1. Pressure regulating and metering and odorization skid is mainly composed of filter, pressure regulator, flow meter, odorizer, instrument and pipe fittings. It is the key equipment for pressure regulation and measurement in LNG gasification station. Features: a. High degree of integration b. Good adaptability c. High reliability Tech1
Container Type Cylinder Group In order to meet the needs of unbalanced refueling of automobiles, CNG refueling stations must be equipped with a high-pressure gas storage system to store high-pressure gas pressurized by the compressor. A reasonable capacity of the gas cylinder group can not only increase the utilization rate and refilling speed of t1
Gas Dispenser CNG dispensers provide you with one pump that‘s capable of dispensing a fast or standard flow. Features : It is mainly consist of intake valve, pipeline filter, break valve, dispensing hose, pressure indicator, etc. The pipe fittings and valves are the products of German STAUFF and American Parker. Technical parameters: No. Name Dispe1
Pressure Regulating Unit CNG Pressure Regulator Skid, the incoming air in the tanker is regulated by the decompression device and then supplied to the downstream device. Features Skid mounted, pre-packaged Automatic control, automatic cut off Technical Parameters Design Capacity 500-3000 Nm3/h Inlet temperature 5~20℃ Discharge ttemper1
Inlet filter metering skid The Inlet filter metering skid supplies downstream equipment after air filtration, metering and pressure adjustment. Features Function: Gas filtering, pressure stabilizing, metering It consists of emergency cut-off valve, pipeline filter, flow meter, buffer tank \ Capacity: Depends on compressors Technical Par1